TW29BN
Beryllium Dome Tweeter
Free. Just your email.

Frequency response and impedance
Level in dB (left axis) and impedance in ohm (right axis), 10 Hz to 20 kHz. The line on each switch above shows how its curve is drawn.
Features
- Beryllium dome for non-resonant high frequency extension
- Two part aluminium faceplate with integrated mechanical decoupling
- Dual balanced compression chambers for improved dynamics
- Dual copper caps for absolute minimum voice coil inductance and minimum phase shift
- High saturation neodymium motor system with T-shaped pole piece for lower distortion
- Non-reflective cast aluminium chamber with optimized damping for improved dynamics
- Shallow flow optimized magnet structure for optimum coupling to rear chamber
- CCAW voice coil for low moving mass
- Long life silver lead wires
- Low resonance frequency for extended range
Features as listed by SB Acoustics. Full details on sbacoustics.com (opens the SB Acoustics website in a new tab)

Specifications
- Nominal impedance
- 4 Ω
- DC resistance, Re
- 3 Ω
- Voice coil inductance, Le
- 0.02 mH
- Free air resonance, Fs
- 700 Hz
- Total Q, Qts
- 0.46
- Electrical Q, Qes
- 0.6
- Mechanical Q, Qms
- 2.1
- Effective piston area, Sd
- 9.6 cm²
- Linear coil travel (p-p)
- 0.5 mm
- Moving mass, Mms
- 0.46 g
- Force factor, Bl
- 3.1 Tm
- Sensitivity (2.83 V / 1 m)
- 95 dB
- Rated power handling
- 80 W
Read from the SB Acoustics datasheet. Check the current datasheet before you rely on a figure.
Design files
SATORI TW29BN FRD and ZMA files, in one zip:
- Frequency responses at 0, 30 and 60 degrees (.frd)
- Impedance (.zma)
- A README and a note on how each curve was made
Plain text files for VituixCAD, XSim, REW and most other crossover tools.
Free. Just your email.
SATORI TW29BN FAQ
What are FRD and ZMA files?
An FRD file holds a driver's frequency response and a ZMA file its impedance, the two curves a crossover simulator needs. Plain text, one point per line.
Which software can open the SATORI TW29BN files?
VituixCAD, XSim and REW, and most other crossover tools that read plain text.
How was this data made?
It was digitised by Artisan Acoustics from the response and impedance graphs in the SB Acoustics datasheet, so it is not a measurement and not an official SB Acoustics file. Each curve is checked against its graph. The datasheet it came from and the conditions printed on it are in the ABOUT.txt note and in the header of each file inside the zip. Use the files at your own risk.
Why is the phase column zero?
The datasheets print level and impedance but not phase. If your simulator needs phase, derive minimum phase there.
Where can I buy the SATORI TW29BN in Singapore or Malaysia?
From Artisan Acoustics, the official SB Acoustics distributor for Singapore and East and West Malaysia. Message us on WhatsApp